Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 220 citations for Dengue Virus Serotype 3 NS1 Protein HEK293 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of 3 mg/mL of protein was added to glow discharged UltrAuFoil holey gold grid (Quantifoil GmbH) using a Vitrobot Mark IV (Thermofisher ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of protein sample was applied to holey carbon grids (Quantifoil, R 0.6/1 Cu 200 mesh) which were H2/O2 glow-discharged for 30 s ...
-
bioRxiv - Immunology 2021Quote: ... Then 3 μl of the protein mixture was applied to a Quantifoil-Cu-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 15 mA for 1 min ...
-
bioRxiv - Biophysics 2021Quote: ... aliquots (3 μL) of the concentrated protein were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3) and blotted for 5 s ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of protein to a glow-discharged QuantiAuFoil R1.2/1.3 300-mesh grid (Quantifoil, Germany) and blotted for 2.5 to 4 s under 100% humidity at 4 °C before plunging into liquid ethane using a Mark IV Vitrobot (FEI).
-
bioRxiv - Biochemistry 2022Quote: Grids (Quantifoil R3/3 Cu300 with 3 nm holey carbon) were glow discharged and 4 µL of sample (8 OD260/mL ...
-
bioRxiv - Biochemistry 2022Quote: A 3 µL of the protein solutions was applied onto the glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). The grids were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2020Quote: ... aliquots (3 μL) of the purified protein concentrated to ~ 10 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3). For KCC3-DIOA samples ...
-
bioRxiv - Molecular Biology 2023Quote: ... A 2.5-3 μL aliquot of protein sample was dropped onto the glow discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with a Vitrobot Mark IV (ThemoFisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2020Quote: Cryo-EM grids were prepared by applying 3 µL sample (at a protein concentration of 1 mg/ml) on glow-discharged holey gold grids (Quantifoil Au 1.2/1.3 300 mesh). Excess sample was removed by blotting with filter paper for 2-3 s before plunge-freezing in liquid ethane (cooled to −181 °C ...
-
bioRxiv - Immunology 2020Quote: An aliquot of 3 μl purified protein of rNLRP1-rDPP9 or rNLRP1FIIND S969A-rDPP9 complex was applied to holey carbon grids (Quantifoil Au 1.2/1.3, 300 mesh), which were glow-discharged for 30 s at middle level in Harrick Plasma after 2 min evacuation ...
-
bioRxiv - Molecular Biology 2023Quote: ... The purified virus was applied onto glow-discharged electron microscopy grids covered with holey carbon (Quantifoil, SPT Labtech, Melbourn, UK), blotted ...
-
bioRxiv - Biophysics 2020Quote: ... 2.5 μl samples of GDN-purified proteins at a concentration of 1.5-3 mg ml−1 were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 or R0.6/1 Au 200 mesh). Excess liquid was removed in a controlled environment (4°C and 100% relative humidity ...
-
PSGL-1 inhibits HIV-1 infection by restricting actin dynamics and sequestering HIV envelope proteinsbioRxiv - Microbiology 2020Quote: ... A 3.5 µL virus sample solution was applied onto a glow discharged copper grid coated with holey carbon (R2/1; Quantifoil, Jena, Germany) prior to plunge-freezing ...
-
bioRxiv - Biophysics 2022Quote: UltraAUfoil R1.2/3 (Quantifoil Micro Tools GmbH) grids were glow-discharged on both sides for 30 s at 15 mA using a Pelco Easiglow ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 microliters of the purified virus sample was pipetted onto a glow-discharged R2/1 Quantifoil grid (Quantifoil Micro Tools GmbH, Jena, Germany), blotted for 2.5 seconds ...
-
bioRxiv - Molecular Biology 2019Quote: ... Cryo-EM grids were prepared by application of 3.5 µl of the sample containing purified Ccr4-Not:ribosome complexes onto R3/3 copper grids with 3 nm continuous carbon support (Quantifoil) and vitrification in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2022Quote: KRASGTPase/BRAFWT/MEK1SASA/14-3-3 complex in SEC buffer was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, 400 mesh) and vitrified using a Leica EM GP ...
-
bioRxiv - Microbiology 2024Quote: ... Sample volumes of 3.5 µl (8 OD260 per ml) were applied to grids (Quantifoil, Cu, 300 mesh, R3/3 with 3 nm carbon) which had been freshly glow-discharged using a GloQube (Quorum Technologies ...
-
bioRxiv - Molecular Biology 2021Quote: Copper grids with holey carbon support film (R3/3, Quantifoil) and a 2 nm pre-coated continuous carbon layer on top were glow discharged at 2.2 × 10-1 mbar for 20 s ...
-
bioRxiv - Biochemistry 2022Quote: ... R3/3 copper grids with a 2 nm carbon coating (Quantifoil) using a Vitrobot mark IV (FEI ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μl was applied to a freshly glow-discharged grid (Quantifoil R0.6/1 Cu 300 mesh grid ...
-
bioRxiv - Immunology 2024Quote: ... 3 µL aliquots were applied to UltrAuFoil gold R0.6/1 grids (Quantifoil) and subsequently blotted for 6 seconds at blot force 0 ...
-
bioRxiv - Biochemistry 2022Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash-frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2022Quote: ... An aliquot of 4 μL protein sample of Spike protein was applied onto a glow-discharged 300 mesh grid (Quantifoil Au R1.2/1.3) and GraFuture™-RGO grid which was supported with a thin layer of RGO (reduced graphene oxide) ...
-
bioRxiv - Biophysics 2020Quote: ... and applied 3 μL to glow discharged EM grids (Quantifoil R2/2 400 mesh). The GFP portion of this substrate consisted of residues 1-229 ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μL of sample was applied to 200-mesh copper R2/1 grids (Quantifoil), which were glow-discharged twice using a Pelco EasyGlow instrument ...
-
bioRxiv - Cell Biology 2020Quote: All samples were imaged on carbon coated 3 mm gold EM finder grids (Quantifoil). Bead test and calibration samples were made by adding 2 µl of 175 nm fluorescent bead solution(Thermo Fisher PS-Speck) ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl sample was applied to 1.2/1.3 or 0.6/1 UltrAuFoil grids (Quantifoil) (Russo and Passmore ...
-
bioRxiv - Molecular Biology 2022Quote: ... 2–3 μL of sample solution was applied to a holey carbon grid (Quantifoil R2/1 ...
-
bioRxiv - Biophysics 2023Quote: 3 μL of sample was applied on glow-discharged Au200 R2/1 grids (Quantifoil), and the excess liquid was removed by blotting for 4 s (blot force 3 ...
-
bioRxiv - Molecular Biology 2022Quote: ... Samples (3 μl) were applied to Quantifoil 1.2/1.3 Cu 300 holey-carbon grids (Quantifoil) glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella) ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μl of the resulting mixture was spotted onto glow-discharged copper EM grids (Quantifoil 300 Au mesh ...
-
bioRxiv - Molecular Biology 2023Quote: ... Samples (3 μl) were applied to Quantifoil 2/1 Cu 300 holey-carbon grids (Quantifoil) glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella) ...
-
bioRxiv - Microbiology 2023Quote: ... sample aliquots of 3 µL were applied onto UltrAuFoil R2/2 grids (300 mesh, Quantifoil). Grids were blotted for 1 s at 10°C with 100% relative humidity and immediately plunge frozen into liquid ethane using a Vitrobot Mark IV system (TFS) ...
-
bioRxiv - Biophysics 2020Quote: ... The protein was spotted onto UltraAuFoil 1.2/1.3 gold grids (Quantifoil) plasma cleaned using an Ar/O2 gas mix ...
-
bioRxiv - Cell Biology 2021Quote: 3 mm gold EM grids with a holey carbon film (R 2/2, 200 mesh; Quantifoil Cat no ...
-
bioRxiv - Biophysics 2019Quote: ... 3 µL of the mixture was applied to glow discharged R1.2/1.3 400 mesh grids (Quantifoil). Grids were blotted with filter paper 494 (VWR ...
-
bioRxiv - Molecular Biology 2019Quote: ... The sample (3 µl) was applied to glow discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil). Grids were blotted for 1.5 s at 16° C or 22° C and ∼100 % humidity and plunge-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Physiology 2021Quote: ... 3 µL of the vortexed dispersion were placed on glow discharged carbon-coated grids (Quantifoil, D) for 1 minute ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µL of purified PPSA was applied to glow-discharged holy grids (Quantifoil, Cu200, R2/2) for 30s ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of the sample was applied to a hydrophilized grids (Quantifoil, R1.2/1.3+2nm carbon) with an additional 2 nm layer of amorphous carbon ...
-
bioRxiv - Molecular Biology 2020Quote: 3 μL of sample was applied onto a holey carbon grid (Quantifoil, Cu, R1.2/1.3, 300 mesh) rendered hydrophilic by a 30 s glow-discharge in air (11 mA current with PIB-10) ...
-
bioRxiv - Plant Biology 2021Quote: Concentrated PSII solution (3 µl) was applied on glow-discharged holey carbon grids (Cu Quantifoil R1.2/1.3) that were vitrified for cryo-EM structural determination using a Vitrobot FEI (3 s blot at 4°C and 100% humidity) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sample (3 μL) was applied to freshly glow-discharged Au 300 mesh R1.2/1.3 grids (Quantifoil) in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL was applied to Ultrafoil grids (R1.2/1.3, Au/Au, 300 mesh, Quantifoil Micro Tools GmbH) that had been glow-discharged for 2 min using a Pelco easiGlow (Ted Pella ...