Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 430 citations for 7 4 Aminobenzamido 4 hydroxynaphthalene 2 sulfonic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2022Quote: A volume of 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Molecular Biology 2019Quote: ... 4 ul of sample was applied to glow-discharged R2/2 gold grids (Quantifoil) which were blotted for 5 s and plunge-frozen in liquid ethane with a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl sample was applied onto Quantifoil grid Rh/Cu 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 µl sample was applied onto Quantifoil grid Cu/Rh 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Biochemistry 2023Quote: ... pristine graphene-coated R2/4 grids (Graphenea) were initially used for optimisation purposes but 2 nm formvar/amorphous carbon R2/2 grids (Quantifoil) were used for data collection ...
-
bioRxiv - Biochemistry 2019Quote: ... 2 μL of crystal solution was deposited on each side of a glow-discharged holey carbon EM grid (Quantifoil 2/4), and the grid was processed with a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Molecular Biology 2020Quote: The grids were prepared by applying 4 µL of each complex at ∼70 nM to 400 mesh holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools). The grids were blotted for 1.5 sec at 4°C ...
-
bioRxiv - Cell Biology 2024Quote: EM support grids (Au grids 200 mesh, carbon or SiO2 foil, R2/2 or R1/4, Quantifoil) were glow discharged with a Pelco easiGlow for 90 sec at 15 mA ...
-
bioRxiv - Biophysics 2023Quote: ... 200 mesh R1/4 or R2/4 Quantifoil holy carbon gold grids (Quantifoil®, Grossloebichau/Jena Germany). were glow discharged in Pelco easiGlow (Ted Pella ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µl of this mixture was applied on a glow-discharged Quantifoil R2/2 grid (Quantifoil Micro Tools GmbH) and flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Microbiology 2024Quote: ... 4 μL of the cell mixture was applied three times onto glow-discharged copper EM grids (R2/2, Quantifoil), followed by plunge freezing into liquid ethane/propane ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Cell Biology 2020Quote: ... or holey SiO2 R1/4 TEM grids (Quantifoil) to allow for more robust correlation and cells were plunge frozen on a Vitrobot Mark IV (FEI ...
-
bioRxiv - Cell Biology 2022Quote: ... Grids (200 Mesh Cu SiO2 R1/4, Quantifoil) were plasma cleaned for 30 s before plunging ...
-
bioRxiv - Plant Biology 2020Quote: ... 4 μL of cell culture was blotted onto R 1/4 SiO2-coated 200-mesh gold EM grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Biophysics 2019Quote: 3.5 ul of sample of doublets (∼4 mg/ml) was applied to a glow-discharged holey carbon grid (Quantifoil R2/2), blotted and plunged into liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Plant Biology 2019Quote: ... 4 µL of mat3-4 cell culture was blotted onto R2/1 carbon-coated 200-mesh copper EM grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Biophysics 2019Quote: 3.5 μl of microtubule fraction sample (∼4 mg/ml) purified from WT Chlamydomonas was applied to glow-discharged holey carbon grids (Quantifoil R2/2), blotted and vitrified in liquid ethane using the Vitrobot Mark IV (FEI Company) ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Biophysics 2021Quote: Gold EM grids with R1/4 holey SiO2 film (Quantifoil) were glow-discharged in a EasiGlow (Pelco ...
-
bioRxiv - Cell Biology 2019Quote: ... R1/4 or R1/20 (Quantifoil Micro Tools, Jena, Germany) were employed in this study ...
-
bioRxiv - Biophysics 2023Quote: 200 mesh Au grids with R1/4 SiO2 foil (Quantifoil) were glow-discharged for 90 sec at 0.38 mBar and 15 mA using a Pelco easiGlow device ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Molecular Biology 2019Quote: ... 2.4 μl of 0.12 mg/ml of the protein preparation were applied to glow-discharged holey carbon grids (Quantifoil, QF 2/1, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Neuroscience 2022Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh, Quantifoil Micro Tools) were additionally coated with a 20-25 nm carbon layer (MED 020 ...
-
bioRxiv - Cell Biology 2024Quote: ... with holey R 1/4 carbon film (Quantifoil Micro Tools GmbH) were glow-discharged for 30 seconds at 5 mA using an EasiGlow system (Pelco ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2023Quote: ... Gold grids with SiO2 film (Quantifoil, Au 200 mesh, R 1/4) were glow- discharged and coated with 20 µg/ml fibronectin solution for 30 min ...
-
bioRxiv - Biophysics 2021Quote: ... with 12-nm-thick holey R1/4 and R1.2/20 SiO2 film (Quantifoil) were used for the experiments ...
-
bioRxiv - Cell Biology 2021Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh grid, SiO2, Quantifoil Micro Tools) were glow-discharged and UV irradiated for 30 min for sterilization before being immersed in cell culture medium in 35-mm IBIDI μ-Dish ...
-
bioRxiv - Synthetic Biology 2023Quote: 4 µl of sample was adsorbed onto holey carbon-coated grid (Quantifoil, Germany) that was glow-discharged ...
-
bioRxiv - Microbiology 2023Quote: ... This mixture was applied to the front (3.7 µL) and to the back (1.3 µL) of carbon-coated copper grids (R2/2, Cu 200 mesh; Quantifoil) previously glow-discharged (2 mA ...
-
bioRxiv - Biophysics 2020Quote: ... 4 µl sample was applied to each freshly glow-discharged grid (Quantifoil, R1.2/1.3). The grids were then plunge-frozen in liquid ethane ...
-
bioRxiv - Biophysics 2023Quote: ... HeLa cells were trypsinized and seeded at a density of 0.5 – 0.7 X 105 cells/mL on carbon-coated gold Quantifoil grid (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2021Quote: ... 4 μl of cell suspension was applied to holey carbon R2/1 Cu grids (Quantifoil) and plunge-frozen on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2019Quote: ... 4 μL of sample was applied to glow-discharged EM grids (R2/1 copper, Quantifoil), blotted twice from the back for 3.5 s and vitrified in liquid ethane–propane using a Vitrobot Mark IV (ThermoFisher) ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μl of sample was applied to glow discharged Quantifoil 300 mesh 1.2/1.3 (Quantifoil) grids at 4 °C and 90-100% humidity ...
-
bioRxiv - Cell Biology 2024Quote: Quantifoil R2/1 or SiO2 R1/4 gold grids (both Quantifoil Mirco Tools GmbH, Germany) were briefly washed in chloroform and placed on drops of poly-D-lysine (100 µg/ml) ...
-
bioRxiv - Biophysics 2024Quote: ... 4 µl of this sample was then applied to plasma-cleaned holey carbon grids (Quantifoil) and plunge frozen with an FEI vitrobot mark IV at 4°C and 100% humidity.
-
bioRxiv - Biochemistry 2020Quote: ... 4 µL of sample was applied to Quantifoil Cu R 1.2/1.3 grids (Quantifoil Microtools GmbH) which has undergone a plasma discharge and were vitrified in liquid ethane using a Vitrobot MkIV plunge freezer (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... Aliquots of 4 µl were applied to glow-discharged 300 mesh R1.2/1.3 Au grids (Quantifoil) using a Vitrobot Mark VI (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... Each glow-discharged Quantifoil R2/4 200 mesh copper grid (Quantifoil Micro Tools GmbH, Jena, Germany) was then deposited with 4 µL sample and plunge-frozen in liquid ethane using a Vitrobot Mark IV (TFS ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μL of Kapβ2•HNRNPH2 was applied to a 300 mesh copper grid (Quantifoil R1.2/1.3) that was glow-discharged using a PELCO easiGlow glow discharge apparatus at 30 mA/30 s on top of a metal grid holder (Ted Pella) ...
-
bioRxiv - Biophysics 2019Quote: ... Perforated carbon film-covered microscopical 200 mesh grids (R1/4 batch of Quantifoil, MicroTools GmbH, Jena, Germany) were cleaned with chloroform and hydrophilised by 60 s glow discharging at 8 W in a BAL-TEC MED 020 device (Leica Microsystems ...
-
bioRxiv - Biophysics 2020Quote: ... 0.2 mM ATP) and 4 μl were applied to glow-discharged 1.2/1.3 holey gold grids (Quantifoil) before plunge freezing in liquid ethane using a Vitrobot (FEI/Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2019Quote: ... 4 µl of the sample were applied onto 300 mesh R1.2/1.3 UltrAuFoil Holey Gold Films (Quantifoil), that had been previously plasma treated for 30 seconds using a 15 mA current operating under atmospheric gases using a glow discharger (Electron Microscopy Sciences) ...
-
bioRxiv - Biochemistry 2021Quote: 4 µl of 20-100 nM RZZSF filaments were deposited on freshly glow-discharged Formvar/Carbon (Quantifoil) film supported copper grid Cu400 (Sigma Aldrich ...