Labshake search
Citations for Quantifoil Micro Tools :
651 - 700 of 751 citations for 6 Chloro 2 4 chlorophenyl N N dimethylimidazo 1 2 α pyridine 3 methanamine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2024Quote: ... The mixture was deposited onto freshly glow-discharged grids (R2/1 Quantifoil) for 1 min ...
-
bioRxiv - Cell Biology 2023Quote: ... a 200-mesh gold grid with Silicon Dioxide R2/1 film (Quantifoil) was coated with Matrigel as reported in the protocol ...
-
bioRxiv - Biochemistry 2021Quote: ... A freshly glow-discharged holey-carbon grid (QF R2/1 300 mesh, Quantifoil) was mounted to a Vitrobot cryoplunger (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2022Quote: ... holey support film type R2/1 on 200 mesh copper grid (Quantifoil, Germany) that was previously glow discharged under the following conditions ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 0.6/1 300 mesh; Quantifoil) were incubated with a thiol reactive ...
-
bioRxiv - Biochemistry 2024Quote: ... The sample was applied to Holey carbon grids (3.5/1, 400 mesh, Quantifoil) at 4 °C ...
-
bioRxiv - Cell Biology 2023Quote: ... Dissected tissues were placed on 200 mesh Molybdenum R2/1 EM grids (Quantifoil) immediately after dissection ...
-
bioRxiv - Plant Biology 2023Quote: ... H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil). Grids were glow-discharged for 20 s in the presence of air using a current of 20 mA ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Quantifoil grids (UltraAuFoil R 0.6/1, Au 300 mesh, Quantifoil MicroTools, Jena, Germany) were treated by plasma cleaning (Harrick Plasma ...
-
bioRxiv - Biophysics 2020Quote: ... then positioned on a holey carbon TEM grid (Quantifoil R2/1, Cu, 200-mesh) pre-clipped into an Autogrid assembly (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: ... applied to glow-discharged holey carbon grids (R2/1, 200 mesh, Au, Quantifoil, Germany), and the NE was spread onto the grid by fine glass needles ...
-
bioRxiv - Cell Biology 2020Quote: ... reinhardtii cells were deposited onto 200-mesh copper EM (R2/1, Quantifoil Micro Tools) and vitrified using a Vitrobot Mark 4 (FEI Thermo Fisher Scientific) ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −3 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: ... applied to glow-discharged holey carbon grids (R2/1, 200 mesh, Au, Quantifoil, Germany), and the NE was spread onto the grid by fine glass needles ...
-
bioRxiv - Biophysics 2024Quote: Plunge freezing of cells was performed on R2/1 SiO2 copper 200 mesh (Quantifoil) grids ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×105 spores/mL) were placed on nickel grids (Quantifoil, Beijing, China) for 15 min and germinated in 0.1 M KOH for 30 min at 30°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... UltrAuFoil R1.2/1.3 or R0.6/1 300 mesh gold grids (Quantifoil Micro Tools GmbH) were glow discharged on both sides for 1.5 mins on a PELCO easiGlow glow discharge unit (20 mA ...
-
bioRxiv - Microbiology 2021Quote: ... before being vitrified on carbon-coated Au grids (R06/1, 200 mesh; Quantifoil, Jena, Germany).
-
bioRxiv - Cell Biology 2021Quote: For each glow-discharged copper grid (Quantifoil Cu 200 mesh, holy carbon film R2/1) 4 μl of the supernatant were applied ...
-
bioRxiv - Molecular Biology 2021Quote: ... Ribosome–EF-G complexes were applied to EM grids (Quantifoil 3.5/1 μm, Jena Bioscience) covered with pre-floated continuous carbon ...
-
Structure of the Human Signal Peptidase Complex Reveals the Determinants for Signal Peptide CleavagebioRxiv - Biochemistry 2020Quote: ... or Cu 200 Holey Carbon R2/1 grids (Quantifoil, for samples containing 1.5 mM FFosC). In both cases ...
-
bioRxiv - Biophysics 2019Quote: ... The best ice distribution and particle density was obtained with 0.6/1 UltrAuFoil grids (Quantifoil).
-
bioRxiv - Molecular Biology 2022Quote: ... The sample was applied onto freshly glow-discharged Au 300 mesh R0.6/1 grids (Quantifoil) in a Vitrobot Mark IV at 4°C ...
-
bioRxiv - Cell Biology 2023Quote: A volume of 4µl of cells was deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2019Quote: ... We then used a glow-discharged Quantifoil EM grids (R2/1, Cu 300 mesh; QUANTIFOIL Company) to gently touch the powder for several times ...
-
bioRxiv - Molecular Biology 2021Quote: ... The sample-covered carbon was then adsorbed to an EM grid (Quantifoil R3.5/1, Jena Bioscience) and blotted for 9 s using a Vitrobot Mark IV (ThermoFisher ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... the mixture was applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −5 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2024Quote: ... 3.5 μL of the culture were applied onto glow-discharged copper EM grids (R2/1, Quantifoil), automatically blotted and plunged into liquid ethane/propane (Tivol et al ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 μl of the washed cells were introduced to Au grids (R2/1, 200 mesh; Quantifoil). The grids were fixed in 4% PFA (in TBS ...
-
bioRxiv - Biophysics 2019Quote: ... Cryo-EM grids (Quantifoil R2/1 Cu mesh 200-300 or Quantifoil R1.2/1.3 Cu mesh 300) were glow discharged with air plasma in a Cressington 208 carbon coater with glow discharge unit for 90 s (10 mA/0.1 mbar air pressure ...
-
bioRxiv - Biochemistry 2022Quote: ... Solutions were adjusted to OD600≈10 and applied to carbon-coated holey copper grids (Quantifoil R2/1). Grids were glow-discharged for 30 s in oxygen/argon atmosphere of a plasma cleaner (Gatan Solarus 950 ...
-
bioRxiv - Microbiology 2021Quote: ... 200-mesh copper grid with holey carbon film (R2/1 Cu 200, Quantifoil Micro Tools GmbH, Germany). The sample was blotted with filter paper and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Microbiology 2020Quote: ... CryoET samples were prepared using copper grids with holey carbon support film (200 mesh, R2/1, Quantifoil). The grids were glow-discharged for 30 seconds before we deposited 5 μL cell solution on them ...
-
bioRxiv - Neuroscience 2021Quote: Sample volumes of 3.5 µl were applied to freshly glow-discharged R3.5/1 holey carbon grids (Quantifoil) and vitrified using a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Biochemistry 2022Quote: TEM gold grids with Holey Carbon support film (Quantifoil Micro Tools GmbH, Au 200 mesh R3.5/1) were glow-discharged in a plasma cleaner (Diener electronic GmbH ...
-
bioRxiv - Molecular Biology 2023Quote: Minicells were vitrified on QUANTIFOIL® R0.6/1 or R1.2/1.3 holey carbon grids (Quantifoil Micro Tools) using a Vitrobot Mark IV (Thermo Fisher Scientific).
-
bioRxiv - Biophysics 2023Quote: ... 10 µL of samples were placed on top of a glow-discharged Au200 R2/1 grids (Quantifoil) and incubated in a 100%-humidity controlled environment ...
-
bioRxiv - Molecular Biology 2020Quote: ... applied to plasma-cleaned 200-mesh Cu R2/1 or 300-mesh Au R1.2/1.3 grids (both Quantifoil) and plunge-frozen in liquid ethane ...
-
bioRxiv - Biophysics 2019Quote: ... Cells were cultivated on Gold Quantifoil grids (R2/1, Au 200 mesh grid, Quantifoil Micro Tools, Jena, Germany). Additional carbon (20–25 nm ...
-
bioRxiv - Biophysics 2020Quote: ... with 2.3 M sucrose9 and transferred to holy carbon finder grids (R3.5/1 Copper NH2 - Quantifoil, Jena, Germany). Sections were stored at 4 °C until further processing.
-
bioRxiv - Biochemistry 2021Quote: ... 1 mM TCEP and adsorbed to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3) for 10 s ...
-
bioRxiv - Microbiology 2020Quote: ... Five microliters of cell suspension were deposited on holey carbon electron microscopy grids (200 mesh, R2/1, Quantifoil), which had been freshly glow-discharged for ∼30 seconds ...
-
bioRxiv - Immunology 2021Quote: ... The resulting EV suspension was spotted onto a glow discharged holey carbon mesh copper grids (Quantifoil, R2/1) and incubated at room temperature for 4 mins 45 seconds before 5μL of 0.22μm filtered 2% (v/v ...
-
bioRxiv - Microbiology 2022Quote: Cryo-ET samples were prepared using copper grids with holey carbon support film (200 mesh, R2/1, Quantifoil). The grids were glow-discharged for ∼30 s before depositing 5 µl of cell solution onto them ...
-
bioRxiv - Biophysics 2023Quote: Three microliters of the purified CLC-2 or CLC-2/AK-42 mixture was applied to glow-discharged copper Quantifoil R1.2/1.3 or R2/1 holey carbon grids (Quantifoil). Grids were incubated for 15 s ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1.5 µL of fibril solution was applied to freshly glow-discharged R2/1 holey carbon film grids (Quantifoil). After the grids were blotted for 12 seconds at a blot force of 10 ...
-
bioRxiv - Biochemistry 2023Quote: ... 3.5 μL of HTNV-L at 1 µM was deposited on glow-discharged (25 mA, 45 s) UltraAuFoil 300 mesh R1.2/1.3 grids (Quantifoil). The grid was blotted for 3s (blot force 1 ...
-
bioRxiv - Microbiology 2020Quote: ... mobilis Zm4 or Zm6 cells were applied to glow-discharged holey carbon grids (Quantifoil R3.5/1 Cu 200-mesh) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... A volume of 4 μL cell suspension at a concentration of 3.07-3.5×107 cells/ml was directly applied to glow-discharged holey carbon R2/1 Cu 200 mesh grids (Quantifoil). After 5 s back-side blotting ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μL of sample were pipetted onto a freshly glow discharged (PELCO easiGlow, 25 mA, 45 sec) 300 mesh Cu 0.6/1 grid (Quantifoil) and blotted for 4 s at strength 4 ...