Labshake search
Citations for Quantifoil Micro Tools :
651 - 680 of 680 citations for 6 4 METHOXY PHENYL 2 PHENYL PYRAZOLO 1 5 A PYRIMIDINE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... Protein-DNA complexes were applied to ultra-gold foil grids with holey gold support and 300 mesh size (R 0.6/1,Quantifoil Micro Tools GmbH); grids were flash-frozen as described [21] and were stored in liquid nitrogen until use.
-
bioRxiv - Cell Biology 2023Quote: ... 4 µL of cell suspension was applied on 200-mesh R ¼ SiO2-film covered gold grids or 200-mesh R2/1 carbon-film covered copper grids (Quantifoil Micro Tools) (for P ...
-
bioRxiv - Microbiology 2023Quote: ... 3µL of each sample was was pipetted onto a freshly glow-discharged Quantifoil R2/1 grid (Quantifoil Micro Tools GmbH, Großlöbicha, Germany), then blotted to remove excess sample and plunge-frozen into a mixture of liquid ethane and propane cooled in a bath of liquid nitrogen using a Vitrobot Mk 4 cryo-plunger (41) ...
-
bioRxiv - Biochemistry 2024Quote: Samples were prepared by applying the polymerized R-β-Actin actin to freshly glow-discharged Quantifoil 3.5/1 on 200 mesh copper grids (Quantifoil GmbH, Germany), using a Leica GP2 (Leica Microsystems GmbH ...
-
bioRxiv - Biochemistry 2022Quote: ... An aliquot of 3.5 μl of sample was placed on the glow-discharged cryo-EM grid (Quantifoil R1.2/1.3 or Quantifoil R2/1), blotted and plunge-frozen in liquid ethane using a Mark VI Vitrobot instrument maintained at 100% humidity with blot force 20 and blot time of 3 seconds ...
-
bioRxiv - Molecular Biology 2021Quote: ... DRD1-SKF81297-LY3154207-miniGs-Nb35 complex at the concentration of 13 mg mL−1 were applied individually onto glow-discharged holey carbon grids (Quantifoil, Au200 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of the sample was applied to a glow-discharged R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of diluted sample was applied to a glow-discharged (R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2022Quote: Three microliters of Ct80S-RAC pull-out sample at 200 nM concentration was applied on holey carbon grids (Quantifoil R2/1 grid, Quantifoil Micro Tools, GmbH) and plunged-frozen into liquid ethane using a Vitrobot (FEI) ...
-
bioRxiv - Microbiology 2020Quote: Usually 5 μL of liquid culture (OD680 ~ 0.3) was pipetted onto holey carbon-coated copper grids (R2/1, 200 mesh, Quantifoil Micro Tools, Jena, Germany). The grids were blotted from the reverse side and immediately plunged into the liquid ethane at liquid nitrogen temperature atmosphere using a Vitrobot ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 microliters of the purified virus sample was pipetted onto a glow-discharged R2/1 Quantifoil grid (Quantifoil Micro Tools GmbH, Jena, Germany), blotted for 2.5 seconds ...
-
bioRxiv - Microbiology 2022Quote: ... 5 µl of bacteria diluted to OD = 0.15 in PBS were deposited on a glow-discharged Quantifoil R2/1 holey carbon grids (Quantifoil Micro Tools GmbH, Germany) and 3 µl gold particles (10 nm BSA tracer ...
-
bioRxiv - Biochemistry 2022Quote: ... three microliters of concentrated phage particles were added to a freshly glow-discharged Quantifoil R2/1 grid (Quantifoil Micro Tools GmbH, Großlöbicha, Germany) and plunge-frozen with a Vitrobot Mk IV into a 50:50 mixture of liquid ethane:propane52
-
bioRxiv - Microbiology 2022Quote: Three-microliter aliquots of all AdSDV capsid populations (~1 mg/mL) were applied to glow-discharged Quantifoil holey carbon grids with a thin layer of carbon (Quantifoil Micro Tools GmbH) and vitrified using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μL of sample (10 μM EGFP in PBS) was deposited onto glow-discharged grids (Electron Microscopy Science and Quantifoil – see Table 1), prior to blotting the grids from the sample-side for 3 seconds.
-
bioRxiv - Microbiology 2023Quote: 3 µL of the purified FL or truncated RSV NC sample were applied to a glow-discharged R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: ... A suspension containing a mixture of 10 nm protein A coated colloidal gold (Aurion) and Ebola VLPs was applied with a volume of 3 µl on a glow discharged EM grid (Quantifoil, 200 Mesh, R2/1). The grid was blotted using No.1 Whatman paper for 3 sec from the back-side in a chamber with controlled humidity set to 70% and the temperature set to 24°C.
-
bioRxiv - Microbiology 2019Quote: 3 μl of purified complex at 1 to 3.6 mg/ml were applied to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3). Grids were blotted for 3 s at 100% humidity at 22 °C and frozen in liquid ethane using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biophysics 2020Quote: Samples were prepared for CryoEM by applying 5 μl freshly purified Cx46/50-lipid nanodisc complex (∼2.5 mg mL-1) to a glow-discharged holey carbon grid (Quantifoil R 1.2/1.3, 400 mesh) for 10 seconds ...
-
Cryo-EM structure of a eukaryotic zinc transporter at a low pH suggests its Zn2+-releasing mechanismbioRxiv - Biochemistry 2022Quote: ... and 3 μl of the protein solution was applied to glow-discharged (45 s) Quantifoil R2/1 300-mesh gold grids (Quantifoil Micro Tools GmbH, Germany). The grids were blotted with standard Vitrobot filter paper for 2.5 s at 4 °C under 100% humidity and plunged into liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Bioengineering 2023Quote: ... 3.0 µl aliquots at a concentration of 0.87 or 1.0 mg/ml of the spikeD614G-binder sample or the spikeOmicron-binder sample were applied onto glow-discharged carbon-coated copper grids (Quantifoil R2/1, 400 mesh), blotted for 4.0-8.0 s ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3), after which ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μL of ∼100 nM (A260 4.0 or 6.0) mitoribosome sample was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/1 copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Biochemistry 2024Quote: ... Approximately 3.5 μl of the solution was applied onto freshly glow-discharged and graphene oxide-coated TEM grids (Quantifoil R2/1, Cu 200 mesh) and plunge-frozen into liquid ethane by a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Bioengineering 2024Quote: ... LCNP or EV suspensions in PBS (∼1 × 1012 particles/mL) were deposited on 300-mesh lacey carbon-coated copper grids (Quantifoil Micro Tools GmbH, Germany). The grids were previously glow-discharged for 45 s using an Emitech K100X glow discharge system (Quorum Technologies Ltd. ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of the apoferritin samples with 1.5 mg/ml or 0.2 mg/ml were applied onto glow-discharged 200-mesh R2/1 Quantifoil grids (used for the K3 dataset) or 200-mesh R2/1 Quantifoil grids coated with continuous carbon film (Quantifoil, used for the Falcon4 dataset), respectively ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of sample (at the native 1 nM concentration) on glow discharged holey gold grids (Quantifoil Cu 1.2/1.3 400 mesh). Excess sample was removed by blotting with filter paper for 4 sec prior to plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 4 °C ...
-
bioRxiv - Biophysics 2019Quote: ... 3.5 μl aliquots of the recombinant human TIM22 complex (7 mg ml-1) were dropped onto glow discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with a Vitrobot Mark IV (ThemoFisher Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: Cryo-EM grids were prepared by applying 3 µL sample (at a protein concentration of 1 mg/ml) on glow-discharged holey gold grids (Quantifoil Au 1.2/1.3 300 mesh). Excess sample was removed by blotting with filter paper for 2-3 s before plunge-freezing in liquid ethane (cooled to −181 °C ...
-
bioRxiv - Biophysics 2024Quote: ... to produce a fiducial marker along with 0.01% NP-40 and 10 μM tubulin solution with BRB80 buffer and 1 mM GTP before the solution was dropped onto the grids (QUANTIFOIL R 1.2/1.3 Cu 200). The grids were blotted with vitrobot (Thermo Fisher Scientific ...