-
No products found
because this supplier's products are not listed.
Sushama Telwatte, et al.,
bioRxiv - Microbiology 2021
Quote:
... The log-linear relationship between viral load measured by RT-PCR (Abbott Real Time SARS-CoV-2 assay) and RT-ddPCR was determined using GraphPad Prism (version 8.4.1).
-
No products found
because this supplier's products are not listed.
Golam T. Saffi, et al.,
bioRxiv - Cell Biology 2021
Quote:
... and ROS-ID detection kit (Enzo Life Sciences) for general superoxide ...
-
No products found
because this supplier's products are not listed.
Diego Calderon, et al.,
bioRxiv - Genomics 2020
Quote:
... RT-PCR products were cleaned with AMPure XP beads (Beckman Coulter A63880). Next ...
-
No products found
because this supplier's products are not listed.
Rupsa Datta, et al.,
bioRxiv - Cancer Biology 2020
Quote:
... or the Mycoprobe Mycoplasma Detection Kit (R&D Systems).
-
No products found
because this supplier's products are not listed.
Debatosh Das, et al.,
bioRxiv - Plant Biology 2021
Quote:
... Real-time RT-PCR was performed with the qPCR GreenMaster high ROX mix (Jena Bioscience, Germany) and primers shown in Table S1 ...
-
No products found
because this supplier's products are not listed.
Yapeng Su, et al.,
bioRxiv - Bioengineering 2019
Quote:
... MART1and PFK transcripts were analyzed by SYBR Green–based real-time quantitative RT-PCR (qRT-PCR) using specific primers purchased from Santa Cruz. Data were normalized to the expression of RPL19 and are expressed as fold changes.
-
No products found
because this supplier's products are not listed.
Victoria Zyulina, et al.,
bioRxiv - Immunology 2020
Quote:
To silence miR-424 the GFP tagged lentiviral vectors that express antisense hsa-miR-424 (MZIP424-PA-1) and corresponding scramble control lentiviral vectors (MZIP000-PA-1) were purchased from SBI (System Biosciences). Transfection of 293T packaging cell line was performed using calcium-phosphate protocol and infection of target cells was done as previously described (Platzer et al. ...
-
No products found
because this supplier's products are not listed.
Heather J. Painter, et al.,
bioRxiv - Microbiology 2020
Quote:
... Mycoplasma PCR Detection kit (Boca Scientific; cat. no. 25235). If parasite cultures tested positive for Mycoplasma ...
-
No products found
because this supplier's products are not listed.
Jackson M. Baumann, et al.,
bioRxiv - Physiology 2024
Quote:
... SYBR Green based real-time PCR was performed using Apex qPCR Master Mix (Genesee Scientific). PCR conditions were as follows ...
-
No products found
because this supplier's products are not listed.
Uxoa Fernandez-Pelayo, et al.,
bioRxiv - Cell Biology 2024
Quote:
... using the Venor Gem Classic Mycoplasma PCR Detection Kit (Minerva Biolabs).
-
No products found
because this supplier's products are not listed.
Carlos A. Z. Bassetto Jr, et al.,
bioRxiv - Biophysics 2023
Quote:
... The real-time controller (U-RTC, Olympus) used for synchronizing lasers and electrophysiological acquisition ...
-
No products found
because this supplier's products are not listed.
Zachary Compton, et al.,
bioRxiv - Cancer Biology 2023
Quote:
... Cells were imaged by real-time fluorescence microscopy (IncuCyte, Sartorius) at two-hour intervals for five days ...
-
No products found
because this supplier's products are not listed.
Gloria Ha, et al.,
bioRxiv - Cell Biology 2024
Quote:
... Cells were regularly validated as mycoplasma free by a PCR-based mycoplasma detection kit (Southern Biotech).
-
No products found
because this supplier's products are not listed.
V.N. Ngassam, et al.,
bioRxiv - Biophysics 2020
Quote:
Vesicles were monitored in real-time using either epifluorescence microscopy (Nikon Eclipse TE2000 inverted fluorescence microscope (Technical Instruments ...
-
No products found
because this supplier's products are not listed.
Sicong Ma, Samantha A. Howden, Sarah C. Keane,
bioRxiv - Biochemistry 2024
Quote:
... GG-pre-miR-19a and pre-miR-143 were generated by overlap-extension (OE) polymerase chain reaction (PCR) using EconoTaq PLUS 2x Master Mix (Lucigen) with primers listed in Table S1 ...
-
No products found
because this supplier's products are not listed.
Lingling Zhang, et al.,
bioRxiv - Immunology 2023
Quote:
... Fab Fragment Goat Anti-Mouse IgG1 (Jackson ImmunoResearch; Cat#115-477-185; RRID: AB_2632529); Goat Anti-Mouse IgG1 ...
-
No products found
because this supplier's products are not listed.
Julia S. Spear, Katharine A. White,
bioRxiv - Cell Biology 2023
Quote:
... A549 (ATCC CCL-185) and MDA-MB-231 (ATCC HTB-26): DMEM (Corning, MT10013CVV) supplemented with 10% FBS ...
-
No products found
because this supplier's products are not listed.
Dora Pinto, et al.,
bioRxiv - Immunology 2020
Quote:
... NK cells were isolated from fresh blood of healthy donors using the MACSxpress NK Isolation Kit (Miltenyi Biotec, Cat. Nr.: 130-098-185). ADCC was measured using LDH release assay (Cytotoxicity Detection Kit (LDH ...
-
No products found
because this supplier's products are not listed.
Haifeng Zhang, et al.,
bioRxiv - Developmental Biology 2021
Quote:
... using the TSA Plus fluorescein detection kit (Akoya Biosciences ...
-
No products found
because this supplier's products are not listed.
Akshatha N. Srinivas, et al.,
bioRxiv - Physiology 2023
Quote:
... ROS Detection Assay Kit from BioVision (MA, USA); TBARS Assay kit from Cayman Chemicals (MI ...
-
No products found
because this supplier's products are not listed.
Anna-Leigh Brown, et al.,
bioRxiv - Neuroscience 2021
Quote:
... and subsequently bead/size selection of RT/PCR products (TotalPure NGS, Omega Biotek). Three rounds of nested PCR using Phusion HF 2x Master Mix (New England Biolabs ...
-
No products found
because this supplier's products are not listed.
Seyed Soheil Saeedi Saravi, et al.,
bioRxiv - Cell Biology 2023
Quote:
Serum creatinine was measured using a colorimetric detection kit (Cayman Chemical; 700460). Serum samples were treated with creatinine reaction buffer (including Creatinine Sodium Borate ...
-
No products found
because this supplier's products are not listed.
Jessica Avila Lopez, et al.,
bioRxiv - Neuroscience 2023
Quote:
... real-time PCR was performed using the SensiFAST SYBR No-ROX Kit (Cat. No BIO-98005, FroggaBio) using a Rotor-Gene 6000 (Corbett Life Science) ...
-
No products found
because this supplier's products are not listed.
Michael S. Breen, et al.,
bioRxiv - Neuroscience 2019
Quote:
... The e-Myco Mycoplasma PCR Detection Kit (Bulldog Bio, 25233) and the MycoAlert Mycoplasma Detection Kit (Lonza ...
-
No products found
because this supplier's products are not listed.
Joel D. Pearson, et al.,
bioRxiv - Microbiology 2020
Quote:
The 2019-nCoV TaqMan RT-PCR Kit from Norgen Biotek and 2019-nCoV ...
-
No products found
because this supplier's products are not listed.
Cristiana Cruceanu, et al.,
bioRxiv - Neuroscience 2020
Quote:
... Real-time PCR reactions were run in quadruplicate using PrimeTime qPCR Primer Assays (IDT DNA) and PrimeTime® Gene Expression Master Mix (IDT DNA ...
-
No products found
because this supplier's products are not listed.
Dennis J. Doorduijn, et al.,
bioRxiv - Microbiology 2021
Quote:
... + 0.05% human serum albumin (HSA, Sanquin).
-
No products found
because this supplier's products are not listed.
Cassian Afting, et al.,
bioRxiv - Bioengineering 2024
Quote:
Real-time deformability cytometry (RT-DC) was performed using an AcCellerator (Zellmechanik Dresden) mounted on an inverted AxioObserver microscope (Carl Zeiss AG) equipped with a 20x/0.4 Ph2 Plan-NeoFluar objective (Carl Zeiss AG) ...
-
No products found
because this supplier's products are not listed.
William J. Moss, et al.,
bioRxiv - Microbiology 2021
Quote:
... Cell lines were routinely assessed for Mycoplasma contamination by PCR using a Myco-Sniff Mycoplasma PCR Detection Kit (MP Biomedicals). All parasite lines used and generated in this study are listed in Table S1.
-
No products found
because this supplier's products are not listed.
Kirsten Lex, et al.,
bioRxiv - Cancer Biology 2019
Quote:
... Retro-transcription into cDNA was performed using a RT-PCR kit NZY First-Strand cDNA Synthesis Kit # MB12501 (NZYtech). Quantitative PCR (qPCR ...
-
No products found
because this supplier's products are not listed.
Tyler J. Marquart, et al.,
bioRxiv - Cell Biology 2019
Quote:
... and cloned into pCMV-miR (Origene). To generate replication-deficient adenovirus ...
-
No products found
because this supplier's products are not listed.
Kai-Cheng Li, et al.,
bioRxiv - Neuroscience 2024
Quote:
... Real-time ThT fluorescence measurements were taken using a Tecan Spark microplate reader (Tecan). The fluorescence values were measured every 10 - 20□min for 3 - 4□h at excitation and emission wavelengths of 440□nm and 480□nm ...
-
No products found
because this supplier's products are not listed.
Zijian Fang, et al.,
bioRxiv - Pharmacology and Toxicology 2020
Quote:
... HTRF detection reagents (cAMP Dynamic 2 kit, Cisbio) were added at the end of the incubation ...
-
No products found
because this supplier's products are not listed.
Mariska Miranda, et al.,
bioRxiv - Cancer Biology 2021
Quote:
... and detection using the MACH1 Detection Kit as per manufacturer instructions (Biocare Medical, Pacheco, CA, USA).
-
No products found
because this supplier's products are not listed.
Simon J Moore, et al.,
bioRxiv - Synthetic Biology 2020
Quote:
... Real-time plate measurements were recorded in a CLARIOStar© plate reader (BMG Labtech, Germany) at 30°C with 10 seconds of shaking at 500 rpm prior to measurements ...
-
No products found
because this supplier's products are not listed.
Robert J. Yamulla, et al.,
bioRxiv - Cancer Biology 2020
Quote:
We used the ALDEFLUOR detection kit (Stemcell Technologies; Cat#: 01700) to detect ALDH enzymatic activity in primary OSE cells ...
-
No products found
because this supplier's products are not listed.
Yunyun Zhang, et al.,
bioRxiv - Biochemistry 2022
Quote:
... each time for 5 mins before ECL solution was added for signal detection using C-Digit (LI-COR Biosciences).
-
No products found
because this supplier's products are not listed.
Gopal Kushawah, et al.,
bioRxiv - Developmental Biology 2020
Quote:
... PCR products were purified using Favorprep Gel/PCR purification kit (Favorgen) columns or PCR purification kit (QIAgene ...
-
No products found
because this supplier's products are not listed.
Christa Kanstrup, et al.,
bioRxiv - Molecular Biology 2023
Quote:
... PCR products were purified using E.Z.N.A® PCR Cycle Pure kit (OMEGA bio-tek) using the manufacturer’s instructions ...
-
No products found
because this supplier's products are not listed.
Rachel J Harding, et al.,
bioRxiv - Biochemistry 2021
Quote:
... and K2 direct detection camera (Gatan) at 165,000x magnification ...
-
No products found
because this supplier's products are not listed.
Veronica Ferrucci, et al.,
bioRxiv - Genetics 2020
Quote:
... Real-time RT-PCR was performed using ‘RealQquality RQ-2019-nCoV’ kits (Ab Analitica; IVD approved) for detection of the RdRp and E genes (from the SarsCov2 N gene) ...
-
No products found
because this supplier's products are not listed.
Davide Monteferrario, et al.,
bioRxiv - Bioengineering 2024
Quote:
Chromatin immunoprecipitation followed by real-time quantitative PCR (ChIP-qPCR) was performed using the ChIP-IT PBMC kit (53042; Active Motif, Carlsbad CA) according to manufacturer’s instructions ...
-
No products found
because this supplier's products are not listed.
Haley M. Geertsma, et al.,
bioRxiv - Neuroscience 2021
Quote:
... Real-time quantitative PCR was performed using Green-2-Go qPCR Master Mix (Bio Basic cat# QPCR004-S) with 25 ng cDNA per reaction and primers targeting mouse Gapdh (Forward ...
-
No products found
because this supplier's products are not listed.
Oscar Alcazar, et al.,
bioRxiv - Biochemistry 2024
Quote:
... or mouse monoclonal anti-HSA antibody (#66051-1-Ig; ProteinTech; Rosemont, IL, USA). After incubation ...
-
No products found
because this supplier's products are not listed.
Xian Zhou, et al.,
bioRxiv - Immunology 2022
Quote:
... Plates were washed four times and horseradish peroxidase (HRP)-conjugated detection Abs for IgG (Bethyl Laboratories) were added for 1 h at RT ...
-
Formaldehyde Detection assay Kit
Cat# K001-F1,
1.0 ea, USD $380.0
Ask
Shaun P. Stice, et al.,
bioRxiv - Plant Biology 2020
Quote:
... 2016 using a Glutathione (GSH) Colorimetric Detection Kit (Arbor Assays) (9) ...
-
No products found
because this supplier's products are not listed.
Vanessa Kohl, et al.,
bioRxiv - Cancer Biology 2020
Quote:
... ROS were analyzed using the ROS Detection Kit (PromoCell, Heidelberg, Germany) according to the manufacturer’s instructions ...
-
No products found
because this supplier's products are not listed.
Samuel Rivero-Hinojosa, et al.,
bioRxiv - Cancer Biology 2021
Quote:
... Plates were developed by washing 6 times in PBS/0.05%Tween 20 followed by incubation with biotinylated IFN-γ detection antibody (0.5 mg/mL; Mabtech; 2 hours, 37°C). This was followed by a further 6 washes in PBS/0.05%Tween 20 and incubation with avidin DH-coupled biotinylated peroxidase H complex (Vectastain Elite ABC Kit ...
-
No products found
because this supplier's products are not listed.
Nicholas G. Schott, et al.,
bioRxiv - Bioengineering 2024
Quote:
... samples were homogenized with TRIzol RT Reagent (Molecular Research Center, RT 111) and pulverized by mechanical compression ...
-
No products found
because this supplier's products are not listed.
Xavier Prasanna, et al.,
bioRxiv - Cell Biology 2020
Quote:
... Osmium tetroxide (Electron Microscopy Sciences, RT 19130); Epon (TAAB ...