-
No products found
because this supplier's products are not listed.
Yaniv Shlosberg,
bioRxiv - Bioengineering 2023
Quote:
Cyclic voltammetry was done using palmsens4 potentiostat with screen-printed electrodes (Basi), with a graphite working electrode (1mm in diameter) ...
-
No products found
because this supplier's products are not listed.
Donggi Paik, et al.,
bioRxiv - Immunology 2021
Quote:
... for 96-well plate cultures or a turbovap (Biotage) for bacterial tube cultures or eppendorf tube lysates ...
-
No products found
because this supplier's products are not listed.
Brenda C. Shields, et al.,
bioRxiv - Neuroscience 2022
Quote:
... in 24-well plates and maintained in NbActiv4 (BrainBits, NB4) at 37 °C ...
-
No products found
because this supplier's products are not listed.
Hao Zhang, et al.,
bioRxiv - Molecular Biology 2022
Quote:
... A Mouse Relaxin-3 ELISA Kit was purchased from Signalway Antibody LLC (MD ...
-
No products found
because this supplier's products are not listed.
Joy Zhou, et al.,
bioRxiv - Neuroscience 2020
Quote:
... Rabbit polyclonal anti-hyperpolarization-activated cyclic nucleotide-gated channel 1 (HCN1; 1:350; Synaptic Systems), was used to label basket cell axons and pinceau terminals ...
-
No products found
because this supplier's products are not listed.
Zhou Fang, et al.,
bioRxiv - Molecular Biology 2023
Quote:
... The wells of a 96 well plate was coated with an anti-C3 Ab (Complement Technology, TX) to capture the C3-complex in the heart cytosolic fractions ...
-
No products found
because this supplier's products are not listed.
Hannah Donnelly, et al.,
bioRxiv - Bioengineering 2024
Quote:
... Enzyme-linked immunosorbent assays (ELISA) was then carried out as per manufacturer’s instructions (R&D Systems, BMP-2 DuoSet ELISA kit, DY355). Briefly ...
-
No products found
because this supplier's products are not listed.
JM Robinson, et al.,
bioRxiv - Immunology 2019
Quote:
... and LBP (Human Lipopolysaccharide Binding Protein ELISA Kit, Cell Sciences, Inc., Cat# CKH113).
-
No products found
because this supplier's products are not listed.
Benoit P. Nicolet, et al.,
bioRxiv - Molecular Biology 2021
Quote:
... CD34+ cells were seeded at a density of 50.000 cells/well in a 12 well plate in CellgroSGM (CellGenix) supplemented with 100ng/mL human recombinant TPO (CellGenix ...
-
No products found
because this supplier's products are not listed.
Steven J. Grzegorski, et al.,
bioRxiv - Genetics 2019
Quote:
... Prothrombin levels in the expression media and the cell lysate were then quantified by ELISA using a matched-pair antibody set ELISA kit (Affinity Biologicals Inc.; FII-EIA).
-
No products found
because this supplier's products are not listed.
Hannah E. Wilson, et al.,
bioRxiv - Cancer Biology 2020
Quote:
C2C12 cells were plated at approximately 90% confluence in 24-well plates (150,000 cells/well) on D0 and differentiated in 2% horse serum (Atlanta Biologicals) in DMEM with antibiotics ...
-
No products found
because this supplier's products are not listed.
Swayam Prakash Srivastava, et al.,
bioRxiv - Cell Biology 2020
Quote:
... Urine albumin levels were assayed using a Mouse Albumin ELISA Kit (Exocell, Philadelphia, PA).
-
No products found
because this supplier's products are not listed.
Katia K Mattis, et al.,
bioRxiv - Physiology 2022
Quote:
... Single larvae per well of a 96-well PCR plate were homogenised with a 1.4 mm acid washed zirconium bead (OPS diagnostics, USA) in 88 µL ice cold PBS using a MiniG™ 1600 homogenizer (SPEX® SamplePrep ...
-
No products found
because this supplier's products are not listed.
Laura E. Doepker, et al.,
bioRxiv - Immunology 2019
Quote:
Immunolon 2HB ELISA plates were coated with 1 μg ml−1 ZM109 gp120 monomer or C.ZA.1197MB gp41 ectodomain (Immune Technology Corp.) in 0.1M sodium bicarbonate ...
-
No products found
because this supplier's products are not listed.
Jens O. Watzlawik, et al.,
bioRxiv - Neuroscience 2024
Quote:
... the supernatant of each single B cell well was screened for antigen specificity through direct ELISA for targeting full-length monomeric p-S65-Ub protein (Boston Biochem, U-102), free p-S65-Ub peptides 1 and 2 and BSA-conjugated p-S65-Ub peptides 1 and 2 (provided by 21st Century Biochemicals) ...
-
No products found
because this supplier's products are not listed.
E. F. Elsiena Kuiper, et al.,
bioRxiv - Molecular Biology 2021
Quote:
... cells were incubated for 30 minutes with 100μl (for 6-well plate) label mix (2mM CuSO4.5H2O, 8μM Sulfo-Cy3 (or other CyColor)-Azide (Lumiprobe), 20mg/ml Ascorbic acid ...
-
No products found
because this supplier's products are not listed.
Renata Varnaitė, et al.,
bioRxiv - Immunology 2020
Quote:
... SARS-CoV-2 specific IgM antibodies were detected using EDI Novel Coronavirus COVID-19 IgM ELISA kit (Epitope Diagnostics), according to the manufacturer’s instructions ...
-
No products found
because this supplier's products are not listed.
Jiang-An Yin, et al.,
bioRxiv - Genomics 2023
Quote:
... Viral titers of the sgRNA libraries were determined by a 6-point dose response in 6-well plates by puromycin selection and determination of live and dead cells (T.spiezzo, Cellecta) or flow cytometry of RFP+ cells (Brunello ...
-
No products found
because this supplier's products are not listed.
Kyung-Jin Jang, et al.,
bioRxiv - Pharmacology and Toxicology 2019
Quote:
Alpha Glutathione S-Transferase (α-GST): levels were quantified in human model effluent samples from the upper channel using an ELISA kit (DiaPharma). The assay was run following the vendor protocol using a standard curve ranging from 0-64 µg/L ...
-
No products found
because this supplier's products are not listed.
Harriet E. Allan, et al.,
bioRxiv - Cell Biology 2021
Quote:
... Aggregation was stimulated with TRAP-6 (25μM) in a 96-well plate (15 minutes, 750rpm, 37°C; BioShake IQ, Quantifoil Instruments) and fixed with 1% formalin (Sigma) ...
-
No products found
because this supplier's products are not listed.
Isabelle Petit-Härtlein, et al.,
bioRxiv - Biochemistry 2023
Quote:
... 0.1 µL of protein solution and 0.1 µL of reservoir were mixed to equilibrate against 45 µL reservoir solution at 20°C in 96-well CrystalDirect plates (MiTeGen) and automatically imaged in RockImager robot (Formulatrix) ...
-
No products found
because this supplier's products are not listed.
JCR Hernandez-Beltran, et al.,
bioRxiv - Microbiology 2022
Quote:
... Antibiotic plates were inoculated from a master plate using a 96-pin microplate replicator (Boekel 140500). Inoculation plates were prepared by adding 200 µL of overnight culture into each well and incubating at 37 °C with 200 rpm shaking ...
-
No products found
because this supplier's products are not listed.
Diana Cortes-Selva, et al.,
bioRxiv - Immunology 2020
Quote:
... plates were coated with 2μg/mL tetanus (List Labs), diphtheria (Sigma) ...
-
No products found
because this supplier's products are not listed.
Frank Mazza, et al.,
bioRxiv - Neuroscience 2024
Quote:
... as well as a nylon bone (Bio-Serv®, K3580) and paper towel for enrichment ...
-
No products found
Maya Imbrechts, et al.,
bioRxiv - Immunology 2021
Quote:
The binding of the purified recombinant antibodies to the following SARS-CoV-2 antigens was assessed via ELISA: spike glycoprotein (S1) RBD-His (REC31849-500, The Native Antigen Company), RBD(N439K)-His (40592-V08H14 ...
-
No products found
because this supplier's products are not listed.
Hyun Jun Woo, et al.,
bioRxiv - Microbiology 2019
Quote:
... was grown on Brucella agar plates (Becton-Dickinson, Braintree, MA, USA) supplemented with 10% bovine serum (BRL Life Technologies ...
-
No products found
because this supplier's products are not listed.
Kathleen A. Martin, et al.,
bioRxiv - Neuroscience 2023
Quote:
... a magnetic retractor base plate (Fine Science Tools, Part number: 1800-03) was used instead of a stereotaxic frame to allow for more flexible positioning of the animal ...
-
No products found
because this supplier's products are not listed.
Keito Okazaki, et al.,
bioRxiv - Cancer Biology 2020
Quote:
... A Histofine Kit (Nichirei Biosciences), which employs the streptavidin-biotin amplification method ...
-
No products found
because this supplier's products are not listed.
Jennifer A. Noble, et al.,
bioRxiv - Plant Biology 2021
Quote:
... and pLREΔSEEL::GFP seeds were placed on plates containing hygromycin B (20 μg/mL; PhytoTechnology Laboratories, Catalog # H397).
-
No products found
because this supplier's products are not listed.
Vanessa Byles, et al.,
bioRxiv - Cell Biology 2021
Quote:
... using the Red Lysis Kit (Next Advance) and Next Advance Bullet Blender (speed 8 ...
-
No products found
because this supplier's products are not listed.
Xiaoquan Zhu, et al.,
bioRxiv - Cancer Biology 2022
Quote:
... and concentrated using ViraTrap lentivirus purification kit (Biomiga). NIH3T3 or RWPE-1 cells or PC3 or LNCaP at 90% confluence were infected with Lenti-FOXP2 ...
-
No products found
because this supplier's products are not listed.
Jeremy Rich, et al.,
bioRxiv - Molecular Biology 2023
Quote:
... visualized using the polink anti rat kit (GBI Labs) and the peroxidase/diaminobenzidine Rabbit PowerVision kit (ImmunoVision Technologies) ...
-
No products found
because this supplier's products are not listed.
AR Wild, et al.,
bioRxiv - Neuroscience 2021
Quote:
The commercially available CAPTUREome S-palmitoylated protein kit (Badrilla, Leeds, UK) was used in accordance with the manufacturer’s guidelines with three optimizations ...
-
No products found
because this supplier's products are not listed.
Joseph I Aubee, et al.,
bioRxiv - Microbiology 2024
Quote:
... All PCR reactions were purified using The Column-PureTM Clean-Up Kit (Lamda Biotech), according to the manufacturer’s instructions (Lamda Biotech).
-
No products found
because this supplier's products are not listed.
Xammy Nguyenla, et al.,
bioRxiv - Microbiology 2020
Quote:
The FDA-approved drug library containing 1,200 small molecule compounds was stored at 10mM in dimethyl sulfoxide (DMSO) in 384-well master plates (Targetmol, Wellesley Hills, MA). Remdesivir was stored at 10mM in DMSO (T7766 ...
-
No products found
because this supplier's products are not listed.
Hemangi Patil, Kyoung-in Cho, Paulo A. Ferreira,
bioRxiv - Genetics 2024
Quote:
The UbiQuant ELISA kit as directed by the manufacturer (LifeSensors, Malvern, PA) was used to determine the absolute and total amount of ubiquitin and ubiquitylated proteins in the RPE ...
-
No products found
because this supplier's products are not listed.
Livia Mazzini, et al.,
bioRxiv - Immunology 2020
Quote:
ELISA plates were coated with 1µg/mL of purified recombinant Spike S1 Protein (aa 18-676) (eEnzyme, Gaithersburg, MD, USA) or with 1µg/mL Spike-RBD (Arg319-Phe541 ...
-
No products found
because this supplier's products are not listed.
Min Yao, et al.,
bioRxiv - Cancer Biology 2023
Quote:
Cells were seeded in the 24-well glass-bottom cell culture plate (Chemglass, #CLS-1812-024), and used 2-3 days later at 50-80% confluency ...
-
No products found
because this supplier's products are not listed.
Made Harumi Padmaswari, et al.,
bioRxiv - Bioengineering 2024
Quote:
... Analysis of hF9 protein was performed using the Human Coagulation Factor IX Total Antigen ELISA Kit (Innovative Research) following the supplier’s protocol ...
-
No products found
because this supplier's products are not listed.
Minerva Bosch-Fortea, et al.,
bioRxiv - Bioengineering 2023
Quote:
... 50 µl of emulsions/well were transferred 24-well plates treated with 25 μg/ml poly(L-lysine)-graft-polyethylene glycol (PLL-g-PEG, SuSoS).
-
No products found
because this supplier's products are not listed.
Adam T. Waickman, et al.,
bioRxiv - Immunology 2020
Quote:
... 96 well NUNC MaxSorb flat-bottom plates were coated with 2 μg/ml flavivirus group-reactive mouse monoclonal antibody 4G2 (Envigo Bioproducts, Inc.) diluted in borate saline buffer ...
-
No products found
because this supplier's products are not listed.
Stefania Di Cio, et al.,
bioRxiv - Bioengineering 2023
Quote:
... endothelial and fibroblast cell) spheroids were formed in 96 ULA well plates by mixing iPSC-derived cardiomyocytes (iCell Cardiomyocytes, Fujifilm Cellular Dynamics, Inc.), cardiac endothelial and fibroblast cells in the ratio 4:2:1 ...
-
No products found
because this supplier's products are not listed.
Zachary T. Olmsted, et al.,
bioRxiv - Neuroscience 2020
Quote:
... hiPSCs were seeded onto freshly coated 6-well plates 3 days prior to transduction with premade LV-CAG-eGFP lentivirus (Kerafast FCT149, 1 × 108 CFU/ml). Polybrene (2 μg/ml ...
-
No products found
because this supplier's products are not listed.
NV DiBenedetto, et al.,
bioRxiv - Microbiology 2023
Quote:
... The same procedure is used for the Toxin B ELISA but N4A8 monoclonal antibodies (BBI solution) diluted at 4ng/ml in PBS was used for the capture antibodies and the T4G1 monoclonal antibodies previously coupled to biotin were used as detection antibodies (BBI solution ...
-
No products found
because this supplier's products are not listed.
Thanh Hoang, et al.,
bioRxiv - Neuroscience 2020
Quote:
... Platinum plate electrode tweezers (Protech International Inc.) were used to deliver two 50 ms pulses (75 V with a 1 s pause between pulses ...
-
No products found
because this supplier's products are not listed.
Darius Sulskis, Johannes Thoma, Björn M. Burmann,
bioRxiv - Biophysics 2021
Quote:
... tablet as well as with 100 U of DNAse (ArcticZymes) for 30 min and subsequently lysed with a Q700 sonicator (Qsonica ...
-
STING agonist
Sold for research purposes only.
Cat# 3688.0, SKU# 3688-1 mg,
Inquire
Ask
Charbel Alfeghaly, et al.,
bioRxiv - Molecular Biology 2023
Quote:
... as well as 1μM PD0325901 (Axon Medchem, 1408; CAS: 391210-10-9), 2μM XAV939 (Cell guidance systems ...
-
No products found
because this supplier's products are not listed.
Oscar A. Campos, et al.,
bioRxiv - Molecular Biology 2021
Quote:
... plates with gradually decreasing amounts of SC amino acid powder (Sunrise Science Products) were prepared ...
-
No products found
because this supplier's products are not listed.
Thomas Eng, et al.,
bioRxiv - Systems Biology 2021
Quote:
... 100 μL of DMSO extracted indigoidine was added to 96-well flat-bottomed microplates (Corning Life Science Products, Corning, NY). Indigoidine was quantitated by measuring the optical density at 612 nm wavelength (OD612 ...
-
No products found
because this supplier's products are not listed.
Syed Moiz Ahmed, et al.,
bioRxiv - Cancer Biology 2019
Quote:
Endogenous TOP1cc were detected by Human Topoisomerase ICE kit (Topogen, TG1020-0) following the manufacturer’s instructions ...